E-mail:sales@unique-cons.com
Tel:+86-371-63699132
Fixed Structure Inspection
Settlement Observation Points: Designated personnel must check daily.
Clearance Zone: No material within 2 meters of the foundation. Report water accumulation immediately.
Geological Abnormalities: If exceeds standards within 16 hours, activate the professional inspection team for parameter reset.
Bolt Connections: Use a vernier caliper to ensure threaded exposure of standard section connection bolts remains within 3-4 threads.
Bolt Alignment: Check with a level gauge; installation angle deviation must be ≤0.1%.
Welding Cracks: Inspect critical nodes (boom, tower cap, slewing ring) with a magnifier. Darkened weld surfaces indicate potential cracks.
Paint Damage: If fish-scale peeling covers 5m², suspend operations and conduct magnetic particle testing for subsurface cracks.
Gear Inspection: Remove inspection end cover; check lubricant discoloration/hardening with a flashlight.
Rotation Test: Use a specialized wrench to rotate the slewing base smoothly for 3 revolutions without mechanical aid.
Hook Inspection: Use 5x magnifier to check wear on critical sections. Replace if wear exceeds 12% of original尺寸.
Pulley Inspection: Replace if radial wear exceeds 30% of wire rope diameter. Missing guards require equipment.
Wire Rope Test: Conduct no-load test with 500kg sandbag; observe rope arrangement during 5m hoisting.
Brake Test: Technicians wearing harnesses must simulate power failure; trolley must stop within 30 seconds.
Cable Management: Check cable tie integrity. Use epoxy board to support damaged cable slots.
Control Box: Test contact terminals with a voltage tester; replace components if erosion depth >30% after 50 operations.
Grounding: Measure resistance; halt operations if exceeding 1mΩ. Lightning grounding points require 15-day soil humidity monitoring.
Moment Limiter: Calibrate to ensure error ≤1/500 of rated value.
Wind Speed Alarm: Third-party device must trigger 5 minutes before Level 10 winds, with uninterrupted 360-second alert.
Obstacle Avoidance: Add ultrasonic calibration procedures in fog/haze conditions.
Counterweights: Verify quantity against nameplate; recalculate if error >1/400 of manufacturer’s specification.
Hook Block Rollers: Must protrude ≥7mm above running surface. Track clearance requires temperature-compensated calibration.
Operator Certification: Quarterly license required to access control panel’s six-color keypad.
Third-Party Validation: Certifications must be updated one week in advance.
Total Assembly Diagram: Must match technical department’s blue stamp and crane’s steel imprint.
Dynamic Records: Manually dial detection channels; lock data promptly. Shift records archived by document controllers.
Maintenance Logs: Handwritten notes cannot replace computer-generated five-color spectral fault analysis reports.
Wind Conditions:
Level 3+ winds: Focus on foundation water monitoring.
Level 6+ winds: Install cross-slings for enhanced anchoring, even if inspections pass.
Post-Storm Checks: Re-test grounding mechanical integrity after thunderstorms.
Night/Rain Inspections: Deploy 4-person team to monitor metal strain and voltage drops.
Three Musts Principle:
Operator-certificate alignment.
Complete warning signage deployment.
Environmental safety boundaries met.
Defect Handling: Mark issues in shift logs; both parties must revisit sites with markers before signing.
Recurring Issues: If a fault recurs 3 times in 2 months, suspend operations for 10 days for expert redesign evaluation.
Address cross-lifting safety zones, power phase balance, and fog compensation.
Obtain unanimous team approval before lifting approval tags.
QR Code Tracking: Generate unique codes for each inspection point. Upload 9-grid photos + 5-second videos within 15 minutes of rectification.
Approval Chain: Requires production leader and triple-inspector confirmation for log entry.
Note: This checklist mitigates but cannot eliminate all risks. Operate personnel must maintain continuous inspection cycles (daily/shift/emergency) to achieve quantitative closed-loop safety control.